Lietuvių klb.
  • Windows

Central Wiring Switch Boxes

Our central wiring switch boxes have been designed to simplify the wiring process. Using our wiring centres in your application means that the actuator, boiler and pump connections are wired from a single point.
UH1 SCREEN HM.UH4.PGV2.Angle PRINT HM.UH8 Angle.PRINT HM.UH8 RF.Angle PRINT

Heatmiser UH1

The Heatmiser UH1 is designed to be used in conjunction with our 12v Network thermostats. The UH1 provides central switching and is therefore ideally situated next to the underfloor heating manifold.

Eight zones can be controlled as well as providing an output for a hot water cylinder. On demand from any zone, a 230v output is provided to switch the relevant zone actuators, underfloor heating pump and valve. A volt free connection is supplied for boiler making it compatible with almost all boilers. Up to 6 actuators can be connected to each zone. An option is provided to turn the zone 8 into a radiator zone. In this mode the underfloor heating pump, valve and boiler are not enabled when there is a call for heat from zone 8.

4 Zone Control NO
8 Zone Control OK
12v Thermostats OK
230v Thermostats NO
Wireless Thermostats NO

Heatmiser UH4

The Heatmiser UH4 can be used in conjunction with our mains thermostats. The UH4 provides central switching of up to 4 zones actuators as well as providing an output for a hot water cylinder, the system boiler and pump.

When used for underfloor heating, an option is available to use zone 4 as a conventional radiator zone. Up to 6 actuators can be connected to each zone.

4 Zone Control OK
8 Zone Control NO
12v Thermostats NO
230v Thermostats OK
Wireless Thermostats NO

Heatmiser UH8

The Heatmiser UH8 can be used in conjunction with our mains thermostats. The UH8 provides central switching of up to 8 zones actuators as well as providing an output for a hot water cylinder, the system boiler and pump.

When used for underfloor heating, an option is available to use zone 8 as a conventional radiator zone. Up to 6 actuators can be connected to each zone.

4 Zone Control NO
8 Zone Control OK
12v Thermostats NO
230v Thermostats OK
Wireless Thermostats NO

Heatmiser UH8-RF

The Heatmiser UH8-RF is designed to be used in conjunction with our wireless thermostats. The UH8-RF provides central switching and is therefore ideally situated next to the underfloor heating manifold. Eight zones can be controlled as well as providing an output for a hot water cylinder. On demand from any zone, a 230v output is provided to switch the relevant zone actuators, underfloor heating pump and valve. A volt free connection is supplied for the boiler, making it compatible with almost all types of boilers. Up to 6 actuators can be connected to each zone. A software option in our wireless thermostats allows you to configure which zones are underfloor heating and which are radiators. The RF Switch can be paired to the UH8-RF in order to offer a wireless boiler link.

4 Zone Control NO
8 Zone Control OK
12v Thermostats NO
230v Thermostats NO
Wireless Thermostats OK

 

FeaturesUH1UH4UH8UH8-RF
RF Switch Compatible No No No Yes
RF Boost Compatible No No No Yes
Slimline-RF, Touch-RF, neoAir Compatible No No No Yes
No. Heating Zones 8 4 8 8
No. HW Zones 1 1   1
Neon Indication No Yes Yes Yes
DIN Rail Mounting No Yes Yes Yes
Supply 230v AC 230v AC 230v AC 230v AC
Relay Load Max 3A 3A 3A 3A
Total Load 5A 5A 5A 5A
IP Protection IP20 IP20 IP20 IP20
Dimensions (L,H,D) mm 220x290x70mm 384x148x60mm 384x148x60mm 384x148x60mm

2 Channel Receiver & RF/Neo Boost

The Heatmiser Boost and RF Switch are surface mounting for easy installation.

HM.Repeater Angle Switch 300x180

Heatmiser Boost

The Heatmiser Boost is our surface mount repeater for the RF and Neo System.  The Heatmiser Boost is designed to extend the communication between the RF Thermostats and Wiring Centre and the neoStat/neoAir & neoHub.


Features Boost
Compatibility Slimline RF, Touch-RF, UH8-RF, Neo System
Supply 230v AC
Dimensions 108x90x24mm

Heatmiser RF Switch

The Heatmiser RF Switch is a 2 channel receiver. It can cater for a single heating zone and the hot water cylinder as well as providing a boiler enable output. Output indications are provided and the unit is surface mount for easy installation.

In addition, the RF Switch can act as a wireless boiler enable link from the UH8-RF 8 Zone Wiring Wiring Centre.

 

 FeatureRF Switch
Compatibility Slimline-RF
Touch-RF
neoAir
UH8-RF
No. Of Heating Zones 1
No. of Hot Water Zones 1
Boiler Output 1
Mounting Type Surface
Relay Load Max 3A Resisitive
Total Load Max 9A Resistive
Supply 230v AC
Dimensions (L,H,D) 108x90x24mm
 

Naujienlaiškis

Pasidalink su draugais

Submit to FacebookSubmit to Google PlusSubmit to TwitterSubmit to LinkedIn